Contactor 65A 4Pole

Ush 115,000

Product SKU : CT C3X2-65-00-04-MU7

Availability : In Stock

 
 
 
Advantages
• It is a fast switching operation
• It is simple in construction
• It provides protection
• Lower power consumption
• High load capacity
• It is suitable for both AC and DC devices.
• Fast switching
Applicable scope
CJ  C3X2 AC Contactor is used in AC 50Hz/60Hz circuit with rated insulating voltage of 690V, rated
working voltage of 400V and rated working current from 9A-95A in AC-3 utilization Category.
•It is used to making or breaking the circuit and for frequent start AC motors from a distance.
It can also be used as electro-magnetic starter when matching with thermal relay to protect the
circuit against overload.
•Conform to IEC/EN 60947-1  ,IEC/EN 60947-5-1
Operation and installation conditions
Type Operation and installation conditions
Installation class III
Pollution degree 3
Compliant standards IEC/EN 60947-1, IEC/EN 60947-5-1
Certification mark CE
Enclosure protection degree CJ  C3X2〜32: IP20; CJ  C3X2-40-95: IP10;
Ambient temperature Operation temperature limits: -35'C ~+70C Normal operation temperature range: -5 C ~+40 C . The 24-hour average temperature should not exceed +35 C . For use beyond the normal operation temperature range.
Altitude Not exceeding 2000 m above sea level
Atmospheric conditions The relative humidity should not exceed 50% at the upper temperature limit of +70 C . A higher relative humidity is allowed at a lower temperature, e g. 90% at+20C - Special precautions should be taken against occasional condensation due to humidity variations
Installation conditions The angle between the installation surface and the vertical surface should not exceed ±5°.
 Additional Information

Main circuit parameter Technical performance
Contactor model  
Rated insulation voltage Ui (V) 690V
Rated impulse withstand voltage Uimp (kV) 8kV
Rated making capacity Making current: 10x|e (AC-3) or 12x le (ACV)
Rated breaking capacity Breaking current: 8x|e (AC-3) or 10xle (AC-4)
  1.2x106
Electrical life (cycles) 1.2x107
1.2x106
  0.8x106
  1.2x107
Mechanical life (cycles) 1x107
0.9x107
  0.65x107
Main contact 3NO
Matching thermal overload relay LR2-36
LR2-93
Built-in auxiliary contact 09-32A1 NO or 1NC ; 40-95A 1NO+1NC
Coil control power supply 24,110,220, 230, 240,415V
24,36,48,110,127,220,230,240,380,415V
Control voltage (70% ~ 120%) Us
(20% ~ 65%) Us
   
Coil average power (VA) Start CJ  C3X2-09-18 40-60
CJ  C3X2-25-32 50-70
CJ  C3X2-40-65 160-120
CJ  C3X2-80-95 190-250
Hold CJ  C3X2-09-18 9.5
CJ  C3X2-25-32 8-11.4
CJ  C3X2-40~65 13-24
CJ  C3X2-80-95 17-30
  AC CJ  C3X2-09-32 1~3
Heat CJ  C3X2-40~65 4~8
dissipation(W) CJ  C3X2-80-95 6~10
  DC   -